Anything and everything that is dumped down the drain winds up in the sewers and lift stations, from grease, garbage, toilet paper, human waste and food to industrial waste. Fast Food restaurants are adding significant loading to a collection system. A collection system is not a sterile environment. As long as there is food for the bacteria to grow, they will grow in the collection systems. The real control is in making sure the right types of bacteria grow in the collection system. Basically, the collection systems can be thought of as one large holding tank or Equalization tank prior to the Wastewater Treatment Plant. Many municipalities have miles and miles of pipes, and numerous lift stations prior to a wet well, and then the actual wastewater treatment plant. Maintenance on these pipes can be costly and time consuming, as well as incur some safety concerns. Bacteria, if given even the slightest chance, will grow anywhere there is sufficient food. Typically, there always is some type of small biofilm in all sewer collection pipes. Usually the growth is slow, due to low BOD loading and high flow of water causing enough movement or even pressure from the lift stations. The biofilm is relatively small, and sloughs off quickly with rain and normal flow. In effect, a miniature RBC unit can be created in the collections systems with the right conditions. Typically, the flow is enough to cause the biofilm to slough off without causing problems. In cases where easily degradable organic compounds are discharged to a system, a very rapid biomass growth can occur. If the industrial or institutional discharger uses large amounts of rolling or cutting oils, Grease or sugars in the processes, has dipping baths where biofilms are allowed to grow, or septic water is allowed to collected in tanks onsite, and then this is discharged into the sewers, the bacteria in the system will quickly grow on these types of substrates. If the optimum environment is not present, such as sufficient N, P or lower pH, or sufficient mixing and Dissolved air, then a slimy biofilm will develop instead of floc. Remember, bacteria need what we call the Critical 5 regardless of whether they are in the pipes, in a holding tank, the sewers at the plant or the final wastewater treatment plant. Ok, so what exactly are the "Critical 5 plus one"? I have never heard of that. There are 5 critical measurements that should be monitored and controlled to effectively run a biological treatment plant efficiently; Temperature, DO, Ammonia, Ortho-phosphate and pH. Typically most sewers have a pH of around 7-7.5, mixing and flow through the pipes generally give enough DO to the system. Temperature is not usually able to be changed, but is not too bad. Since most pipes are well below the freezing level underground, activity will slow in the winter, but never freeze up. N and P are high in normal household waste due to human biosolids, but when high industry or institutional, such as hotels, restaurants or strip malls with fast food restaurants are around, then these variables can get out of line and cause problems. What are you growing in your pipes? Let's take a look at some pipes, wet wells, collections systems and lift stations and see just what can happen.
Here you can see not only grease in the water, but growing on the walls of the pipe and up into the collection system.
In these two lift stations you can see a grease ledge on the side of the lift station, and growing around the pipes, chains and floats.
In some lift stations, hard grease balls or "floating turtles" will form. These can block up pipes and cause problems with pumps if allowed to grow too large and cause obstructions. Some lift stations can get significantly crusted with thick grease and solids.
Lift stations can be extremely small or up to 5 million gallons a day! Obviously, the larger the lift station or wet well, and the longer the holding time in the vessel, the more solids and grease and biofilm that can build up.
Some lift stations even have multiple chambers,
This is a manhole 20 feet from a small restaurant. Look at how much grease and solids are built up in this small area. This restricts the flow and eventually may cause problems in the restaurant with back-ups. The solution- a small amount of bacteria were mixed in a bucket of water and poured directly on the surface of the grease to clean out this manhole. It worked! Continual dosage will be required weekly, though since there is no source for recirculation an it gets washed out periodically. Ongoing maintenance kept the manhole from ever building up so many solids again though!
Here is a case of a stretch of over 1-2 miles that a city had where the pipes were growing a large biofilm directly in the pipes and had to jet out the lines weekly.
Significant levels of slime were visible, and sometimes long "ropes" of slime and biomass could be seen snaking through the pipes.
The biofilm, if not jetted out weekly, would build up enough to block off the mains and the laterals. The City had an industrial facility that manufactured metal parts. One of the things used when cutting metal parts is rolling and cutting oils. Their wash water was discharged in the pipes and sent to the city wastewater treatment plant. They actually had two plants in this city, and at both locations, the same thing occurred in both parts of the lines directly after the plant discharges. If any industrial plant has a very high BOD loading, or even one with simple sugars that are easily degradable, and ample time in the pipes to grow, you will get significant growth in your pipes and lift stations. In this case, the flow was low, but the loading was high, so ample time was allowed in the pipes for the bacteria to grow. The problem in this case was there was not enough N and P since it was mostly industrial waste instead of human waste, so a nutrient deficient condition arose, along with septicity, causing the growth of filaments and high polysaccharide slime, which developed into a thick, slimy biomass film. Slime and long filaments formed a majority of the growth along the bottom and sides of the pipe, similar to growth on a RBC unit. Sooner or later it would slough off, and travel a bit down the pipes, until it eventually ran into the part of the sewers where household waste joined the stream. Now large chunks of tissue paper and waste mixed in with the stream, causing larger buildups of biomass, until eventually there were 6-7 ft long solid masses of debris, slime and biofilm. Blockages were common, and line jetting was 1-2 times a week in the summer when temperatures were warm and growth was significantly higher. How do you get around these types of situations instead of jetting a line out manually weekly which is not only time consuming, but costly? Pretreatment is possible- chemical, biological and mechanical methods are ways to address these scenarios. Obviously each plant and problem must be looked at and the correct response for each situation evaluated. Numerous options are available. 1.)A DAF unit can be installed onsite at the plant to not only float out any oils, but add aeration to the stream, so no septicity would occur in the lines, addition of Nutrients can then be added to the stream as it leaves the plant if necessary.
3) Numerous options are available for mixing and aeration of pre treatment tanks, holding tanks or lines. A walk through the plant is recommended to look at the process, see where water is being held, what types of chemicals are used onsite, and how beneficial reuse may be used onsite. Mixing and aeration of tanks can cause less septicity, growth of fungi and slime forming bacteria. One cheap, method that does not require maintenance is the installation of Venturi-type injectors in the incoming pipes to make sure that adequate aeration is in the tanks. No moving parts are involved, so very little maintenance is ever required. We have used these at many pretreatment tanks to supplement oxygen to a system.
Mazzei® Injectors For Primary or Supplemental Aeration Works great at depths less than 5' Utilize standard water pumps for quiet, high-efficiency aeration , Models for 0.125 cfm through 358 cfm Mazzei injectors are the answer for increasing DO levels for water treatment in situations where the use of conventional blower/diffuser aeration would be inefficient, impractical or very expensive. Typical applications where injectors are being used for aeration include ponds or lagoons that are too shallow for surface aerators, STP effluent streams needing a boost in DO, and ammonia and H2S stripping. 4.) Add nutrients to the drains onsite and hope there is sufficient air and mixing in the pipes, at least this would cause less slime growth, and hopefully more floc formation. I would not add bioaugmentation products to the drains, unless you add sufficient nutrients. You already have easily degradable compounds in this sewer, more bacteria without sufficient nutrients would only make it grow faster and develop more slime. A dual program must be implemented if you decided to add bacteria and nutrients. Nutrients alone can be added, but not bugs alone. 5.)Add bleach to the drains at the industrial plant, to kill off any slime that has formed in holding tanks, and make sure that very little biological growth can occur in the sewer pipes, and that all treatment takes place only onsite at the Wastewater treatment plant.- not the best option, but at least a option 6.) Grit removal with mechanical equipment, either screening, a small cone
settling tank or even a plate and frame clarifier. This could include Recovery
of metals and coatings, or even just removal from the sewer system would be an
improvement. 7.) Automatic Pit Evacuator(APE). "A stationary inductor, the
Automatic Pit Evacuator (APE) recirculates 5-12% of the flow and derives its
power from discharge pipes of existing pumps in lift stations, force mains and
wastewater treatment plants. Recirculation occurs through a venturi orifice
fixed in an open-ended housing. 8.) Some collection systems just need a little help with Mother Nature. The small addition of bioaugmentation products can significantly impact the amount of grease and slime build up in a system. Sometimes, a small amount of nutrients are required to be added with the bioaugmentation products if N and P levels are low. Some plants hang bioaugmentation blocks into the lift stations, some add dry product to the wetwells, some restaurants add liquids down the grease traps and some plants use bioaugmentation in their jet trucks to get a handle on the grease and slime. Many options are available. 9.)The Best option would be some type of beneficial reuse program or recapture and reuse onsite of side streams. Without auditing their plant, and knowing exactly their process, or the chemicals involved, this would be hard to speculate at. We work with many outside companies that do this. One man's garbage is another mans treasure. Odor Control issues in lift stations and wet wells Wet wells at the plant can become septic and cause growth of filaments and spirillum
We have had some cases where the flow is so low, that the water in the lift stations or wet wells becomes septic and causes odor control issues for the municipality. Alternative odor control technologies in addition to some of the above solutions mentioned 1.)Peroxide addition- almost always very expensive and destroys some of the biomass cells when added, but kills some of the non desirable bacteria, destroys COD and adds O2 to the water. High BOD Demand can make this a very expensive option. 2.) Sodium nitrate addition- Sometimes, when mechanical means are not available due to location and electricity, air volitalization issues, chemical means can supplement oxygen to a biological system. Typical rule of thumb is 1.4 lbs of oxygen per lb of BOD. When oxygen is not available, Sodium nitrate can be supplemented, ( or any form of nitrate- we have just found the dry sodium nitrate is the cheapest, and safest for handling purposes). Typical dosing rule of thumb 2 lbs of sodium nitrate required per lb of supplemental oxygen needed. 3.) Praxair- injection of pure oxygen to supplement current system- additional information at Environmental Leverage Inc. The Praxair® In-Situ Oxygenation (I-SO™) System dissolves oxygen into wastewater for biological treatment. New environmental regulations require wastewater treatment facilities to reduce hazardous air pollutants due to stripping actions of air spargers and surface aerators. With the development of Praxair's I-SO System, we've combined the advantages of oxygen usage with a low-cost, high-efficiency dissolution process, reducing air emissions and increasing wastewater treatment capacity with minimum capital expenditure. 4.) Pine Blocks or mist systems- Some plants hang pine blocks in the lift stations to overcome any minor odors that are emitted, and some plants set up elaborate mist systems with essential oils to mix with the air, and destroy any airborne odors.
Obviously, there are tons of issues with Collection Systems, lift stations, wet wells and wastewater treatment plants. We hope this issue has at least made you think of some possible things that might be going on in your system, a few options that are available to you besides constant maintenance. Sometimes a small amount of preventative maintenance or proactive treatment can eliminate some of the repetitive maintenance. Call us if you have any questions or have problems with your lift stations and wet wells! We are more than happy to help come out and troubleshoot. I need to get rid of Grease in my lift Station Solid Grease build-up in my
lift stations
Bioaugmentation Solutions for Lift stations, Wet Wells and Collection Systems
BIOCUBEs-Solid
block biological products that are specifically formulated and packaged for use
in lift stations and large restaurant grease traps to remove grease build-up and
help increase degradation capabilities. Lift Station Formulation-MicroClear 207 bacterial formulation is used for softening and degrading food type fat, oils and grease in lift stations but can also be used in any high grease environment. Restaurant formulation-This biological product is a high strength formulation developed to degrade fats oils and grease quickly. It can be used in restaurants, grease traps and drain fields where food based grease is a problem. Sewer formulation-This product is an improved biological product, specifically formulated and packaged for use in sewers to help degrade grease build-up and stop blockage.