What is the difference between BOD, COD or TOC? Why do I have to measure them?
COD or Chemical Oxygen Demand is the total measurement of all chemicals in the water that can be oxidized. TOC or Total Organic Carbon is the measurement of organic carbons. BOD- Biochemical Oxygen Demand is supposed to measure the amount of food (or organic carbons) that bacteria can oxidize. For the purposes of this training, we are going to use the term Biological Oxygen Demand as well, the two terms have been interchanged, but if you are taking a wastewater operators test, stick to the BioChemical term. The purpose of this training is to get the basic understanding of what is going on across, you cannot have a biochemical oxygen demand or biochemical reaction without including biology! We are trying to get the concept across that one of these test methods is using biology, the other two are using strictly chemicals to measure pollution. COD is usually measured and the test is simple and easy to perform with the
right equipment and can be done in 2 hours. BOD usually takes 5 days and TOC
used to require large expensive pieces of equipment that could measure the
sample in minutes, but was cost prohibitive. There are now test in tube kits
that utilize COD digesters to run a test similar to a COD test method. Below are
more Why do I have to measure them? The government came up with these test methods as a way to determine the amount of pollution in a water stream to try to control and limit the amount of chemicals that can pollute the lakes and rivers if left in a final effluent or discharge stream. Some municipalities want to measure the amount of chemicals in the incoming stream in order to asses surcharges as a way of measuring how much additional treatment their plant will have to do in order to get the incoming water clean. It is not only important to know which test you are being measured on, but why, how the sample is pulled and the variations on how they perform the test method. Garbage in, garbage out, correct sampling procedures and methods are critical and can make the difference in violating a permit or not.
Did you know some labs do not add bacterial seed cultures? If there are few or very little bacteria in the sample, it will show that the BOD is low. It there are biocides present, it will show the result as low. If there are high levels of ammonia present in the sample or bits of algae present, a false high BOD reading will show up. If the sample sits for a few days and turns septic before the test is run, it will require more oxygen and if not set up properly, again a false reading will occur. What is Chemical Oxygen Demand?
The use of COD results for wastewater compliance monitoring is increasing. To measure oxygen demand, biochemical oxygen demand (BOD) relies on bacteria to oxidize readily available organic matter during a five-day incubation period. COD uses strong chemicals to oxidize organic matter. Generally, COD is preferred to BOD for process control measurements because results are more reproducible and are available in just two hours rather than five days. By the time you have the results from a five day test, the plant conditions are no longer the same, so real time monitor and control can not be relied upon by the use of BOD. COD is a quick and easy measurement to get a snap in time picture of what is going on in the system, and with trending, long term predictions can be made and monitor and control of the process at the wastewater treatment plant can be optimized and controlled.
For industrial samples, COD may be the only feasible test because of the presence of bacterial inhibitors or other chemical interferences, which would interfere with a BOD determination. COD testing also gives the fast measurements required in many treatment systems for informed decisions regarding process control adjustments. Many industrial and municipal laboratories find that parallel COD and BOD testing is beneficial because the COD test can be used to target a specific BOD range. The need for multiple BOD dilutions is minimized or eliminated. What is Total Organic Carbon?
TOC is often used when levels of organic matter (OM) are low. Total organic carbon is a good parameter to measure and actually a more accurate indication of some of the pollutants that cause the most problems than a BOD test. TOC doesn't differentiate between that portion of organic carbon, which can be metabolized (assimilated). TOC used to be measured by expensive analyzers. Below are some of the older methods with analyzers. Typically TOC analyzers are composed of three primary categories: combustion oxidation, wet oxidation and photocatalytic oxidation. Some analyzers use a combination or mixture of technology.
(1)Combustion Oxidation/ NDIR Method (non-dispersive infrared gas analyzer) (2) WET OXIDATION- Persulfate oxidation / NDIR MethodThere are two types of this method, persulfate oxidation supported with UV (Ultraviolet) irradiation activation and heated persulfate oxidation. (3) CONDUCTIVITY- UV oxidation / Conductivity based TOC methods oxidize the TOC that is present to CO2 using UV radiation typically in the presence of a titanium oxide catalyst. COMBUSTION OXIDATION The combustion method measures total carbon (TC). It requires samples injection by syringe into a high temperature furnace with a platinum or cobalt catalyst. This process oxidizes all of the carbon materials present to CO2.
Newer methodology for TOC Analyses. One type of new methodology for TOC analyses is using closed-loop photocatalytic oxidation. The new TOC methodology includes a titanium dioxide slurry and a 400 nm light source for the oxidation process. The closed-loop TOC system incorporates a closed-loop design to eliminate the need for carrier gases and uses what is called dynamic endpoint detection, where all of carbon in the sample is oxidized to completion. The reaction is measured using a non-dispersive infrared (NDIR) detector. This new technology can directly measure TOC from a single sample eliminating the loss of purgable organics and results in comparable recoveries of various organic compounds when compared to the combustion TOC method. This new methodology can be used for the same applications where the traditional TOC methods have been employed. There are now also Test N Tube reagents that can be used with COD digesters and Spectrophotometer analyzer. The test is performed in two hours, but the cost for capital equipment is nowhere in the same range. The method involves the oxidation of sample carbon to carbon dioxide by persulfate digestion. The carbon dioxide diffuses into a colored pH indicator solution where it is converted to carbonic acid. The resulting color change is directly proportional to the concentration of carbon present in the sample.
There are two completely different tests-a C-BOD test and a BOD test. Many times a C-BOD vs. BOD5 test is needed due to conditions at a plant. In some places where the nitrification of ammonia may not be complete (i.e., incomplete conversion of ammonia (NH3) to nitrate (NO3)) or where too high levels of amines or ammonia are present, false BOD readings may occur. This can occur in municipal lagoons, chemical plants or refineries. For lagoon (pond) treatment systems or other situations where this may occur, it is recommended that a Carbonaceous Biochemical Oxygen Demand (CBOD or Inhibited BOD) should be reported and used in place of 5-day Biochemical Oxygen Demand (BOD5). Nitrification is inhibited so that only the oxidation of COD occurs. What is the difference between BOD vs. CBOD? BOD5 measures the oxidation of carbons and possibly nitrogenous compounds present in a water sample. CBOD only measures oxidation of carbons.
It is rumored that a ferry tipped over and that many of the people who fell in the river got sick or died. This was not due to drowning, but due to the effects of the pollution in the river. The Royal Commission on Sewage Disposal recommended and adopted the BOD5 test in 1908. The duration of the test is normally 5 days. The Average temperature is = 20 degrees C. 300 ml are usually used. Dark Incubation is needed to restrict the growth of algae. The final measurement is usually expressed as O2 mg/l. BOD measures all biodegradable organic carbons, and under certain conditions, oxidizable nitrogen present in the waste. The biochemical oxygen demand (BOD) test tries to closely model an aerobic wastewater treatment system and the natural aquatic ecosystem. It measures oxygen taken up by the bacteria during the oxidation of organic matter. The test usually runs for a five-day period, but can run 7 or 10 days as well, depending on specific sample circumstances. BOD uses and limitations: BOD testing has its widest application in measuring waste loadings of treatment plants, and in evaluating the efficiency of treatment processes. It is of limited use in industrial wastewaters containing heavy metal ions, cyanides, and other substances that may be toxic to the microorganisms.
Unfortunately, the test has flaws. It is usually seeded with the type of bacteria found in municipal plants. The types of bacteria needed in papermills or refineries usually differ in species from the standard procedures method. The hard to degrade organics found in some of these systems also may take longer than 5 days to break down, so a BOD test will give an inaccurate measurement of the amount of pollution that may be present in a waste stream. Well, I guess it is really important to know these terms, how and where I sample my system as well as who runs the tests. .. . What is the difference between C-BOD, Total BOD and N-BOD? Now I am really confused?